From fd0366cfd99e097994f1201518c05439e8ddac6c Mon Sep 17 00:00:00 2001 From: Vanessa Ezekowitz Date: Tue, 3 Feb 2015 02:11:16 -0500 Subject: [PATCH] make pressure sensor turn off if it doesn't have at least one side connected to a source of pressure --- flowing_logic.lua | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/flowing_logic.lua b/flowing_logic.lua index e4eee8a..dce7bc4 100644 --- a/flowing_logic.lua +++ b/flowing_logic.lua @@ -270,7 +270,7 @@ minetest.register_abm({ local sensor = string.match(node.name, "pipeworks:flow_sensor_") local newnode = nil - if my_level > 1 then + if my_level > 1 and (set1 or set2) then newnode = sensor.."loaded" else newnode = sensor.."empty"