Add digiline support to switching station.

Makes the switching station able to send supply and demand
via digilines.
This commit is contained in:
DS-Minetest 2017-03-23 17:45:37 +01:00 committed by Diego Martínez
parent 383f7df22d
commit 6abd857b3f
2 changed files with 57 additions and 4 deletions

View File

@ -2,7 +2,9 @@ default
pipeworks
technic_worldgen
bucket?
mesecons?
mesecons_mvps?
digilines?
intllib?
unified_inventory?
vector_extras?

View File

@ -34,6 +34,9 @@
technic.networks = {}
technic.cables = {}
local mesecons_path = minetest.get_modpath("mesecons")
local digilines_path = minetest.get_modpath("digilines")
local S = technic.getter
minetest.register_craft({
@ -57,12 +60,47 @@ minetest.register_node("technic:switching_station",{
local meta = minetest.get_meta(pos)
meta:set_string("infotext", S("Switching Station"))
meta:set_string("active", 1)
meta:set_string("channel", "switching_station"..minetest.pos_to_string(pos))
meta:set_string("formspec", "field[channel;Channel;${channel}]")
end,
after_dig_node = function(pos)
minetest.forceload_free_block(pos)
pos.y = pos.y - 1
minetest.forceload_free_block(pos)
end,
on_receive_fields = function(pos, formname, fields, sender)
if not fields.channel then
return
end
local plname = sender:get_player_name()
if minetest.is_protected(pos, plname) then
minetest.record_protection_violation(pos, plname)
return
end
local meta = minetest.get_meta(pos)
meta:set_string("channel", fields.channel)
end,
mesecons = {effector = {
rules = mesecon.rules.default,
}},
digiline = {
receptor = {action = function() end},
effector = {
action = function(pos, node, channel, msg)
if msg ~= "GET" and msg ~= "get" then
return
end
local meta = minetest.get_meta(pos)
if channel ~= meta:get_string("channel") then
return
end
digilines.receptor_send(pos, digilines.rules.default, channel, {
supply = meta:get_int("supply"),
demand = meta:get_int("demand")
})
end
},
},
})
--------------------------------------------------
@ -301,6 +339,19 @@ minetest.register_abm({
S("@1. Supply: @2 Demand: @3",
machine_name, technic.pretty_num(PR_eu_supply), technic.pretty_num(RE_eu_demand)))
-- If mesecon signal and power supply or demand changed then
-- send them via digilines.
if mesecons_path and digilines_path and mesecon.is_powered(pos) then
if PR_eu_supply ~= meta:get_int("supply") or
RE_eu_demand ~= meta:get_int("demand") then
local channel = meta:get_string("channel")
digilines.receptor_send(pos, digilines.rules.default, channel, {
supply = PR_eu_supply,
demand = RE_eu_demand
})
end
end
-- Data that will be used by the power monitor
meta:set_int("supply",PR_eu_supply)
meta:set_int("demand",RE_eu_demand)