1
0
mirror of https://github.com/mt-mods/pipeworks.git synced 2024-11-09 20:10:21 +01:00
Commit Graph

17 Commits

Author SHA1 Message Date
Vanessa Ezekowitz
14102d7c3a made storage tanks connect from top/bottom, made storage tank and pipe
textures use the ^ combine operator so they can show the actual liquid going
through the pipes/tanks.
2013-01-05 21:14:09 -05:00
Vanessa Ezekowitz
88bc800ccb minor spacing tweaks, nothing functional 2013-01-04 01:12:39 -05:00
Vanessa Ezekowitz
6419ecb117 First stage of integrating Mauvebic's water flowing code. This is experimental
and doesn't move water yet - but at least it doesn't break anything :-)
2013-01-04 00:15:23 -05:00
Vanessa Ezekowitz
fadd91c744 fixed facedir/rotation bug in placement of expansion tanks. 2013-01-01 18:17:43 -05:00
Vanessa Ezekowitz
dc5617db89 changed default orientation of spigot to make it easier to place. 2013-01-01 18:00:16 -05:00
Vanessa Ezekowitz
1a562d23a8 added a "sealed" entry/exit panel (really just a horizontal pipe with a metal
panel overlayed into the middle).   Also, tweaked pipes to always drop the
empty ones.
2013-01-01 16:30:21 -05:00
Vanessa Ezekowitz
6cca6f9857 revamped pumps so that now they should sit in/on liquid and be connected only
from the top, relegated grates to decorational-only, added outlet spigot.  Got
rid of a few obsolete textures.  Got rid of that whole _x and _z naming thing,
now all directional devices (pumps, valves, spigots, tanks) use facedir.
Valves, spigots no longer auto-rotate to find nearby pipes.
2013-01-01 16:04:05 -05:00
Vanessa Ezekowitz
2efaa35700 Added test object for pneumatic tube autorouting code, made tubes connect to
it and any object that bears groups={tubedevice=1} (connects to any side)
2012-09-17 12:32:47 -04:00
Vanessa Ezekowitz
4a834d17b2 Added pneumatic tubes with their own autoplace code (does not connect to
steel pipes).  Fixed a recursion bug that sometimes caused a stack overflow.
2012-08-24 13:39:29 -04:00
Vanessa Ezekowitz
4597b1b59a Added "expansion tank" that appears if the user stacks tanks upwards.
(Downwards is not checked).
2012-08-22 09:56:45 -04:00
Vanessa Ezekowitz
70ea341bf5 Extended storage tank to show fill level in 10% steps (0% to 100%). 2012-08-22 08:24:42 -04:00
Vanessa Ezekowitz
a66d9a8564 Added outlet grate, made it participate in autoplace algorithm. 2012-08-22 03:43:38 -04:00
Vanessa Ezekowitz
bb168e75e4 made storage tanks' upper/lower fittings and intake grate fitting participate
in pipe autoplace algorithm
2012-08-21 14:49:17 -04:00
Vanessa Ezekowitz
3ddb75217c minor opps/bugfix - devices should not look above/below them normally :-) 2012-08-21 14:38:59 -04:00
Vanessa Ezekowitz
50522aeae9 reorganized code a bit to allow for upcoming rules changes. 2012-08-21 14:32:44 -04:00
Vanessa Ezekowitz
564abfe45a Made storage tank participate in autoplace algorithm. Tuned API a
little to allow for more flexible placement.
2012-08-21 13:52:25 -04:00
Vanessa Ezekowitz
a6641f0d20 Pumps and valves now fully participate in the auto-rotate/auto-route process.
These devices can only be connected to horizontal pipes or to each other.  Note
that only the device being placed and the pipes around it will adapt; if you
have a valve and pump next to one another and they won't connect, put a piece
of pipe at one end to show the auto-rotator which way they should go.  Removal
of a pipe or device will not change the orientation of surrounding devices.
2012-08-19 01:56:30 -04:00