1
0
mirror of https://github.com/mt-mods/pipeworks.git synced 2024-12-27 11:20:26 +01:00
pipeworks/new_flow_logic/flowable_node_registry_install.lua

97 lines
4.2 KiB
Lua

-- flowable node registry: add entries and install ABMs if new flow logic is enabled
-- written 2017 by thetaepsilon
-- use for hooking up ABMs as nodes are registered
local abmregister = pipeworks.flowlogic.abmregister
-- registration functions
pipeworks.flowables.register = {}
local register = pipeworks.flowables.register
-- some sanity checking for passed args, as this could potentially be made an external API eventually
local checkexists = function(nodename)
if type(nodename) ~= "string" then error("pipeworks.flowables nodename must be a string!") end
return pipeworks.flowables.list.all[nodename]
end
local insertbase = function(nodename)
if checkexists(nodename) then error("pipeworks.flowables duplicate registration!") end
pipeworks.flowables.list.all[nodename] = true
-- table.insert(pipeworks.flowables.list.nodenames, nodename)
end
local regwarning = function(kind, nodename)
local tail = ""
if not pipeworks.toggles.pressure_logic then tail = " but pressure logic not enabled" end
--pipeworks.logger(kind.." flow logic registry requested for "..nodename..tail)
end
-- Register a node as a simple flowable.
-- Simple flowable nodes have no considerations for direction of flow;
-- A cluster of adjacent simple flowables will happily average out in any direction.
register.simple = function(nodename)
insertbase(nodename)
pipeworks.flowables.list.simple[nodename] = true
table.insert(pipeworks.flowables.list.simple_nodenames, nodename)
if pipeworks.toggles.pressure_logic then
abmregister.balance(nodename)
end
regwarning("simple", nodename)
end
local checkbase = function(nodename)
if not checkexists(nodename) then error("pipeworks.flowables node doesn't exist as a flowable!") end
end
-- Register a node as a simple intake.
-- Expects node to be registered as a flowable (is present in flowables.list.all),
-- so that water can move out of it.
-- maxpressure is the maximum pipeline pressure that this node can drive.
-- possible WISHME here: technic-driven high-pressure pumps
register.intake_simple = function(nodename, maxpressure)
checkbase(nodename)
pipeworks.flowables.inputs.list[nodename] = { maxpressure=maxpressure }
table.insert(pipeworks.flowables.inputs.nodenames, nodename)
if pipeworks.toggles.pressure_logic then
abmregister.input(nodename, maxpressure, pipeworks.flowlogic.check_for_liquids_v2)
end
regwarning("simple intake", nodename)
end
-- Register a node as an output.
-- Expects node to already be a flowable.
-- upper and lower thresholds have different meanings depending on whether finite liquid mode is in effect.
-- if not (the default unless auto-detected),
-- nodes above their upper threshold have their outputfn invoked (and pressure deducted),
-- nodes between upper and lower are left idle,
-- and nodes below lower have their cleanup fn invoked (to say remove water sources).
-- the upper and lower difference acts as a hysteresis to try and avoid "gaps" in the flow.
-- if finite mode is on, upper is ignored and lower is used to determine whether to run outputfn;
-- cleanupfn is ignored in this mode as finite mode assumes something causes water to move itself.
register.output = function(nodename, upper, lower, outputfn)
checkbase(nodename)
pipeworks.flowables.outputs.list[nodename] = { threshold=threshold, outputfn=outputfn }
if pipeworks.toggles.pressure_logic then
abmregister.output(nodename, lower, outputfn)
end
regwarning("output node", nodename)
end
-- register a simple output:
-- drains pressure by attempting to place water in nearby nodes,
-- which can be set by passing a list of offset vectors.
-- will attempt to drain as many whole nodes as there are positions in the offset list.
-- for meanings of upper and lower, see register.output() above.
-- non-finite mode:
-- above upper pressure: places water sources as appropriate, keeps draining pressure.
-- below lower presssure: removes it's neighbour water sources.
-- finite mode:
-- same as for above pressure in non-finite mode,
-- but only drains pressure when water source nodes are actually placed.
register.output_simple = function(nodename, upper, lower, neighbours)
local outputfn = pipeworks.flowlogic.helpers.make_neighbour_output_fixed(neighbours)
register.output(nodename, upper, lower, outputfn)
end