Commit Graph

29 Commits

Author SHA1 Message Date
Vanessa Ezekowitz
b68a66ef4a Add vertical version of airtight pipe entry
if automatically rotates to connect to the thing you point at, if a connection
is possible.
2013-06-08 01:00:49 -04:00
Anthony
65c4ffde7b Add inventory images for pipes. 2013-03-18 23:00:00 -03:00
Vanessa Ezekowitz
aaacd37c6f Removed node breaker and deployer. These belong in technic, not pipeworks.
Added aliases to avoid unknown nodes/map breakage.  Old code has been moved
into pipeworks/attic/
2013-01-31 18:49:47 -05:00
Novatux
fe0fd68601 Changed the name of some textures for naming conventions. Added deployer and node breaker (most of the code is from Technic, the textures too). 2013-01-20 17:53:17 +01:00
Novatux
b3fcf6734f Added autocrafter.
Fixed a bug where items in mese tubes disappeared whan placing or removing a tube next to it.
2013-01-19 15:37:27 +01:00
Vanessa Ezekowitz
109729cfb2 Added Nore's item transport mod and integrated it into pipeworks
Items can now flow from one chest (or Nore's filter object) to another via the
pneumatic tubes!  Thanks to Nore and RealBadAngel for the code.

Note that this mod has to redefine the default chests and furnaces (see
compat.lua) in order to add some new group definitions so that tubes can
appear to connect to these objects.
2013-01-13 21:45:03 -05:00
Vanessa Ezekowitz
14102d7c3a made storage tanks connect from top/bottom, made storage tank and pipe
textures use the ^ combine operator so they can show the actual liquid going
through the pipes/tanks.
2013-01-05 21:14:09 -05:00
Vanessa Ezekowitz
0a1f90c391 Made pipes able to carry water!
It was just a minor logic error resulting from moving the water flowing code
into it's own file when I originally imported it.  Many thanks to Mauvebic for
writing it!
2013-01-04 01:34:25 -05:00
Vanessa Ezekowitz
6419ecb117 First stage of integrating Mauvebic's water flowing code. This is experimental
and doesn't move water yet - but at least it doesn't break anything :-)
2013-01-04 00:15:23 -05:00
Vanessa Ezekowitz
4eaad14048 Minor tweak to fix missing smooth bend on some T-junctions. 2013-01-01 17:51:55 -05:00
Vanessa Ezekowitz
1a562d23a8 added a "sealed" entry/exit panel (really just a horizontal pipe with a metal
panel overlayed into the middle).   Also, tweaked pipes to always drop the
empty ones.
2013-01-01 16:30:21 -05:00
Vanessa Ezekowitz
6cca6f9857 revamped pumps so that now they should sit in/on liquid and be connected only
from the top, relegated grates to decorational-only, added outlet spigot.  Got
rid of a few obsolete textures.  Got rid of that whole _x and _z naming thing,
now all directional devices (pumps, valves, spigots, tanks) use facedir.
Valves, spigots no longer auto-rotate to find nearby pipes.
2013-01-01 16:04:05 -05:00
Vanessa Ezekowitz
c47d6b02df Added crafting recipes for various objects, with options: If homedecor is
installed, use the plastic sheeting therein.  If not, we define it manually.
If the Technic mod is installed, don't define any recipes at all.  Also removed
the extra "loaded!" messages and tweaked the default pipe alias to point to
something that is actually visible :-)
2012-09-02 12:55:14 -04:00
Vanessa Ezekowitz
4a834d17b2 Added pneumatic tubes with their own autoplace code (does not connect to
steel pipes).  Fixed a recursion bug that sometimes caused a stack overflow.
2012-08-24 13:39:29 -04:00
Vanessa Ezekowitz
83f853d2ae old pipes were overridind the pipeworks:pipe defintion that belongs with the
new pipes.
2012-08-24 10:31:18 -04:00
Vanessa Ezekowitz
50522aeae9 reorganized code a bit to allow for upcoming rules changes. 2012-08-21 14:32:44 -04:00
RealBadAngel
23515f9d3e Update init.lua 2012-08-19 10:48:34 +03:00
Vanessa Ezekowitz
a6641f0d20 Pumps and valves now fully participate in the auto-rotate/auto-route process.
These devices can only be connected to horizontal pipes or to each other.  Note
that only the device being placed and the pipes around it will adapt; if you
have a valve and pump next to one another and they won't connect, put a piece
of pipe at one end to show the auto-rotator which way they should go.  Removal
of a pipe or device will not change the orientation of surrounding devices.
2012-08-19 01:56:30 -04:00
Vanessa Ezekowitz
f574235d1d better pipe end textures, made 'cut' ends also display them. 2012-08-18 22:12:29 -04:00
Vanessa Ezekowitz
f06a6d9b65 minor wording tweak to comments at top. 2012-08-18 21:26:07 -04:00
Vanessa Ezekowitz
9e6f469cde Re-enabled old pipes by default. Only horizontal pipe appears in creative
inventory now (for both old and new), as well as "off" valve and "off" pump.
2012-08-18 21:24:30 -04:00
Vanessa Ezekowitz
4ccb053e03 Total rewrite again. All pipes are now nice and round-looking, and they auto-connect! Also added temporary nodes for pump
and valve (each with an on/off setting - punch to change).  No crafting recipes yet and the pipes still don't do anything
useful yet.  Soon.
2012-08-18 08:46:17 -04:00
Vanessa Ezekowitz
16f50586ba Made the empty/loaded indication at the capped end more prominent. 2012-08-05 23:23:05 -04:00
Vanessa Ezekowitz
7fc2cc1af8 changed the default pipe segment to the aforementioned "short centered"
segment, renamed it to just "pipeworks:pipe" (and pipe_loaded), added
empty/loaded indicator images to the capped ends, removed some redundant
comments
2012-08-05 23:11:50 -04:00
Vanessa Ezekowitz
dad4ba3df2 Added -X, +X, -Y, +Y, -Z, +Z capped stubs and a short centered horizontal
segment.
2012-08-05 22:52:18 -04:00
Vanessa Ezekowitz
151b7f023f rewrote pipeworks to use loops and tables to create the nodes. Requires far
less code now.
2012-08-05 21:29:59 -04:00
Vanessa Ezekowitz
b3765b0df6 disable debug by default 2012-07-31 11:44:23 -04:00
Vanessa Ezekowitz
b5b7e64f40 Fixed pipeworks filenames, tweaked init.lua to match. Whole mode is now
"pipeworks" as it shoulda been, instead of just "pipes".
2012-07-18 13:54:11 -04:00
Vanessa Ezekowitz
104bbf67dd first commit 2012-07-12 17:52:35 -04:00